home *** CD-ROM | disk | FTP | other *** search
/ Light ROM 4 / Light ROM 4 - Disc 1.iso / text / maillist / 1995 / 0295.doc / 000344_owner-lightwave-l _Fri Feb 17 18:33:36 1995.msg < prev    next >
Internet Message Format  |  1995-03-19  |  2KB

  1. Return-Path: <owner-lightwave-l>
  2. Received: by mail4.netcom.com (8.6.9/Netcom)
  3.     id NAA20284; Fri, 17 Feb 1995 13:41:04 -0800
  4. Received: from ix2.ix.netcom.com by mail4.netcom.com (8.6.9/Netcom)
  5.     id NAA20052; Fri, 17 Feb 1995 13:38:53 -0800
  6. Received: from  by ix2.ix.netcom.com (8.6.9/SMI-4.1/Netcom)
  7.     id NAA13917; Fri, 17 Feb 1995 13:38:43 -0800
  8. Date: Fri, 17 Feb 1995 13:38:43 -0800
  9. Message-Id: <199502172138.NAA13917@ix2.ix.netcom.com>
  10. From: dougr5@ix.netcom.com (DOUG RICHARDSON)
  11. Subject: Re: Inside or Outside (The Quest for PAR)
  12. To: Carl Andrew Johnson <cjohnson@crl.com>
  13. Cc: lightwave-l@netcom.com
  14. Sender: owner-lightwave-l@netcom.com
  15. Precedence: bulk
  16.  
  17. You wrote: 
  18.  
  19. >
  20. >In my continuing quest form information regarding the PAR I have to ask 
  21. >this next question. What works best? Internal drives or external 
  22. dirves? 
  23. >I'm concerned about heat buildup in my A4000. Occassionally I keep a 
  24. cold 
  25. >drink on top of it, but I don't hink this is going to help when I get 
  26. >into these LOOOONG redering sessions twhere the machine may bneed toobe 
  27. >on weeks at a time.
  28. >
  29. >Suggestions???
  30. >
  31. >-Carl
  32. >
  33. >
  34.  
  35. Ahhh yes... I do know about heat buildup. My A4000 has
  36.  PAR
  37.  TBC IV
  38.  Ethernet
  39.  AD516
  40.  two Quantum 540 IDE drives
  41.  one Micropolis 1.76gig drive
  42.  one Quantum 240 SCSI II drive
  43.  WarpEngine 40MHz with 32meg ram
  44.  
  45. After installing my last board ( AD516 ) the system would shut down 
  46. after about 5 minutes and the power supply would be very hot. It seems 
  47. to mainly be a power shortage in the supply. I now have an external 
  48. tower case that supplies power to all of the harddrives. I have also 
  49. mounted three extra fans. One large fan on the righthand side blowing 
  50. air in through a filter. One medium fan on the left hand side sucking 
  51. air out past the cards. One small fan blowing on the simms.
  52.  
  53. The power supply no longer gets hot but, the air comming out of the card 
  54. side is very warm. To mount the fans I drilled lots of 1/2 inch holes 
  55. for the vents and some holes for the screws.
  56.  
  57. Looks UGLY but what the heck. BTW if you don't have as much stuff in 
  58. yours you might want to only use the external case to keep the internal 
  59. powersupply in check. You can find 200watt cases for $35.